Streambox: Multiplexing and Automation of GC Sampling
Increase the analytical capacity of your gas chromatograph by automating up to 46 sample streams without format constraints.
Unlimited Automated Sampling for Your GC
Designed and manufactured in-house by Chemlys, the Streambox® heated valve enclosure Streambox add additional injection and selection valves to your GC. It allows you to sequence automated analysis sequences from multiple sources (sampling bags, cylinders, canisters) while preserving the integrity of your complex matrices.
Streambox: Multiply Your Analytical Capabilities
Standard Solution: GC Integration Ready for Employment (up to 16 channels)
The Streambox is a high-performance gas stream selector designed to automate sampling for any gas analyzer (GC, Micro-GC, Mass Spectrometer, or gas sensors). By centralizing your sampling points, it eliminates manual handling and ensures continuous, repeatable monitoring of your processes or laboratory experiments.
Designed to work seamlessly with any analyzer manufacturer, providing a truly universal sampling interface.
-
Direct Control: Native, synchronized operation directly through the GC software interface (e.g., Shimadzu).
-
Scalable Multiplexing: Connection up to 16 samples in basic configuration.
-
Flexible Sample Introduction: Sequential analysis of Tedlar® bags, pressure bottles, canisters or bottles without changing architecture.
Extended Solution: Integrated Automation for Process Projects (up to 46 lanes)
Following the Chemlys philosophy, the Streambox features an autonomous, embedded controller. You no longer need to worry about dedicated workstations or complex software installations. Scalable Architecture: Available in configurations ranging from 4 to 32 streams to adapt to your growing needs.
-
Maximized Capacity: Manage up to 30 streams on standard GC and 46 streams on Micro GC.
-
Advanced Conditioning: Custom automation of sample conditioning (purging, pressure regulation, complex sequence management).
-
System Independence: Independent piloting via an industrial automata dedicated for process integrations and analysis bays.

As a proprietary solution engineered and manufactured by CHEMLYS, Streambox overcomes the physical and chemical constraints associated with challenging gas sampling:
-
Maximum Chemical Inertness (SilcoNert® 2000 Option): Specific surface treatment to prevent adsorption of reactive molecules (H2S, mercaptans, NH3).
-
Cold-Spot-Free Thermal Transfer: Self-regulated heating at 80 °C or 140 °C with heated transfer line directly connected to the GC injector for semi-volatile compounds.
-
Hydrogen & Flammables Safety: Enclosure purge feature using inert gas sweep to eliminate combustible gas accumulation in case of leaks.
-
Gas Sampling Bag Autosampler Version: Integrated micro-sampling pump and rotameter to guarantee highly repeatable sampling at atmospheric pressure.
-
Ergonomic Design & Maintenance: Flexible lateral positioning (left or right side of the GC) and front-access valves under the hood for fast, simple servicing.
The Chemlys Advantage: Engineering & Reliability
Bespoke Sampling Solutions: We design products that evolve with your specific analytical needs, not the other way around.
Hydrogen-Ready Safety: Work with total peace of mind. The Streambox features an inert gas purging system to prevent gas buildup in the event of a leak—a critical safety feature for laboratories transitioning to Hydrogen carrier gas.
Simplified Maintenance: Minimize downtime with our front-access architecture. Valves and critical components are positioned directly under the hood for immediate accessibility and rapid servicing.
A versatile tool with multiple applications, designed to meet your evolving sampling needs.
STREAMBOX adapts to a wide range of containers, including cylinders, canisters, Tedlar® bags, and all other types of gas sampling pouches.
Find the main STREAMBOX box specifications:
| Features | Streambox Specification |
| Valve capacity | Up to 3 valves |
| Stream Capacity (Standard / PLC) | 2 to 16 flows (GC control) — Up to 46 flows (automatic control) |
| Thermal regulation | Self-limited heating (80 °C or 140 °C). Optionally regulated heating 200° C |
| Container compatibility | Sampling bags (Tedlar®...), pressure cylinders, canisters |
| Materials & Passivation | 316L Stainless Steel / Optional SilcoNert® 2000 inert coating SilcoNert® 2000 |
| Safety System | Optional inert gas purge for hazardous/flammable environments |
| Positioning | Left or right of GC |

Gas Sampling Bag Autosampler Version:
Analysis of 16 gas sampling bags on GC-MS QP2010SE SHIMADZU.
control via GC software
Streambox online.
Online process analysis on GC 2030 SHIMADZU.
control via GC software
STREAMBOX for Micro GC
Online analysis of several online streams with a Micro GC
Did an app get your attention? Contact us for more details on the configuration of your STREAMBOX and our other examples of applications!
Frequently asked questions about our STREAMBOX:
Is Streambox® compatible with GC systems other than Shimadzu?
Yes. Although it is natively optimized for direct control by Shimadzu GC software (up to 16 lanes), the equipable version of a stand-alone controller allows you to connect and interface the Streambox with any GC or Micro GC in the market.
How does Streambox handle gas sampling bags at atmospheric pressure?
In its configuration « Bag passer »Streambox incorporates a dedicated sampling pump and a rotameter to extract the gas repeatedly, without altering the matrix or requiring pre-pressure.
Can Streambox handle corrosive or reactive sulfur compounds?
Absolutely. Selecting the passivant treatment option SilcoNert® 2000, reactive compounds such as (H2S, NH3, chlorinated) are transferred without adsorption losses or matrix degradation.